01What it is

Polyurethane (PU) Tubing

Polyurethane (PU) tubing is the highest-volume pneumatic tube in the SPC catalog — the default flexible polymer for general plant air, and the only right answer for constant-flex applications like robotics and tool drops. Two decisions get the right one on the truck: durometer matched to motion (soft 95A for flex, firm 98A for static), and OD matched to the fitting. PU's hard limits are chemistry, heat, and UV — when any of the three is in play, the spec belongs to PA12 nylon or FEP.

Real-world reference Representative polyurethane (pu) tubing
Polyurethane (PU) Tubing — representative product photo
02Why it's needed

Why this matters.

Tips and pointers on when PU is the right call — and when to spec something else. Scroll the strip →

01 · Key point
It lasts under flex.

Elastomer-block-copolymer structure recovers its bend radius without micro-cracking — millions of cycles at proper radius under pressure. The polymer for robot wrists, end-effectors, tool drops.

02 · Key point
It fits tight runs.

3–4× OD bend radius on soft 95A — the tightest of any common tubing polymer. Behind panels, around servos, through cable trays where nothing else will follow.

03 · Key point
It seals first try.

Soft polymer compresses cleanly into PTC collet seals — the most forgiving tubing for push-to-connect. Cut square, push home, pressure up — done.

04 · Pro tip
Match durometer to motion.

Soft 95A for constant flex — robots, tool drops, balancer lines. Firm 98A for static and routed runs — general plant, FRL-to-valve, machine routes.

05 · Where not to use
Oil, coolant, solvent exposure.

Hydrocarbons swell PU and stress-crack the polymer. → Re-spec to PA12 nylon any time the run sees cutting fluid, lube mist, or chemical contact.

06 · Where not to use
Sustained heat above 150°F.

PU softens below working strength as temperature climbs. → Re-spec to PA12 for elevated ambient, or FEP for steam-line proximity and hot-process zones.

07 · Where not to use
UV / outdoor / ozone exposure.

Unstabilized PU embrittles within months of sunlight. → UV-stabilized PU for short outdoor; PA12 for indefinite outdoor or ozone-prone equipment rooms.

03Key selection criteria

What we need to spec it right.

From the machine spec sheet → to the part number. Answer what you know — leave the rest blank — and send.

01 · Input
Measure the existing tube or read the fitting size with a caliper — OD must match the fitting exactly. Metric and inch are not interchangeable.
Metric: 4mm · 6mm · 8mm · 10mm · 12mm · Inch: 1/4" · 3/8" · 1/2"
02 · Input
Set by whether the run flexes on every cycle — soft for motion, firm for static.
95A soft (constant flex — robots, tool drops, balancers) · 98A firm (general / static — plant runs, machine routes)
03 · Input
Read the system gauge; confirm it stays within the PU rating at operating temperature — PU derates significantly at heat, not just room temp.
Typical: 100 PSI · 120 PSI · 145 PSI
04 · Input
Standard compressed air, indoors, moderate temperature. Not for oil, coolant, chemical, or weld-spatter exposure — re-spec to PA12 or FEP.
Indoor general air · Robotics / motion · Outdoor (UV-stabilized PU only) · Food-grade
05 · Input
Specialty variants change the SKU and price tier.
Straight length · Coiled / self-storing · Multi-bore (2 / 3 / 4-bore)
06 · Input
For circuit identification — plant convention varies, but the common code is:
Blue (air) · Black (vacuum) · Red (utility) · Yellow (cylinder supply) · Natural / White (food-grade)
07 · Input
Distributor pricing breaks at roll size — per-roll cost is materially below per-foot. Need multiple length/qty combinations? Add each as its own quote line (e.g., 4× 100-ft + 1× 500-ft = two lines).
Roll sizes: 100-ft · 500-ft · 1000-ft · Format: "qty × roll-size" (e.g., 2 × 500-ft)

Need different sizes, colors, or quantities? Fill the form, add to quote, then fill again — each click is one quote line.

04Choose your solution tier  ·  core differentiator

Whatever your lever — spec, value, or price — SPC has the right brand.

Most distributors sell one brand per product type. SPC's 60-brand portfolio means every Product Type page surfaces three real options matched to how your customer is buying today. Pick the tier; the quote desk handles the cross-reference.

05How to sell this  ·  distributor talk track

The tier conversation closes the deal. The cross-reference catalog wins the next one.

PU lets a pneumatic circuit flex on every cycle without cracking — that's the default tubing for every motion application, plus the highest-volume general-plant line. Recurring revenue is in the rolls; the consultative win is matching durometer to motion profile.
The SPC difference · how distributors actually buy

The 30-second positioning

PU is the highest-volume tubing line in the pneumatic category by a wide margin. The customer is buying it because the application is dynamic. The distributor's edge is durometer selection, color-coded circuit ID, and matching the right PTC fitting line.
Industry Leader tier is the SPC flagship on this line — full durometer range (soft 92A through firm 98A), broad metric and inch OD coverage, food-grade certifications, multi-bore and coiled/self-storing variants, full color range. Documented extrusion tolerance — the spec brand for OEM machine builders and integration houses where tubing failure costs cycle-time.
Tier: Industry Leader tier — deep spec, OEM-grade. Emerging tier — domestic deep-stock for next-day plant utility replenishment. For OEM-build orders where Industry Leader tier range and consistency matter, Industry Leader tier is the right answer; for plant-utility same-day, Emerging tier.

Customer cue → talk move

"Robot end-effector tubing keeps cracking"
Wrong durometer. Quote 95A soft Industry Leader tier; the per-foot premium is small and the avoided downtime pays back in weeks.
"General air drops for the plant"
98A firm PU in 6mm or 1/4" OD, blue, 500-ft rolls + matched PTC fittings. Bundle.
"PU swelling near the coolant tank"
Wrong polymer. Re-route to PA12 nylon — PU is degraded by oils/coolant. Don't leave PU there.
"Outdoor compressor room"
Standard PU is not UV-stable. UV-stabilized for short outdoor; PA12 for indefinite outdoor.
"Food-grade for beverage filling"
Industry Leader tier food-grade PU with FDA certs. Spec the food-grade extrusion in natural or white.
"Self-storing coiled hose for hand-tool drop"
Industry Leader tier coiled PU specialty. Spec by working length, OD, and fitting configuration on both ends.
"Multi-circuit drop in one sheath"
Industry Leader tier multi-bore PU (2/3/4-bore in one extruded sheath). Color-coded bores for circuit ID.
"Standardizing pneumatic tubing"
98A firm PU for general; 95A soft PU for tool drops + robots; PA12 for oil/coolant + high-pressure. Single fitting line covers both PU and PA12 compatibility.
06Where it's used

Industries served.

Each industry below uses this product across the listed areas. Open an industry to see how it fits the rest of its system.

Also applies to Robotics and automation end-effector circuits · Pneumatic hand-tool drops and balancer lines · Soft PU or coiled PU is correct · 98A firm PU at 6mm or 1/4" OD in blue is the deepest-stock configuration. · Pneumatic automation cells, machine OEM builds, integration projects · Multi-circuit drops and cable-management applications · Pneumatic instrument panels and control cabinets · Vacuum-system and pickup-circuit plumbing · Black PU is the convention · Hand-tool blow-off, point-of-use air, operator-station drops

09Install · 8 critical steps

The things that matter on the first install.

Step 01
Cut the tube square with a dedicated cutter and inspect
Use a sharp tube cutter, not a utility knife. Cut face perpendicular to the axis within 1-2°. PU's soft polymer takes a clean cut readily but deforms under side-cutters. Re-cut if angled or torn.
Step 02
Confirm fitting compatibility and match OD precisely
Most PTC fittings (composite, technopolymer, metallic-brass) are PU-compatible — the soft polymer is gripped well by standard collet designs. Verify metric tubing into metric fittings (or inch into inch). 6mm and 1/4" are close but not identical. For coiled/self-storing, end fittings are often barbed-and-clamped or threaded rather than PTC.
Step 03
Mark insertion depth and push fully home
Insertion depth typically 12-22mm depending on OD. Mark with permanent marker. Push straight until bottom — PU is forgiving on insertion angle but bottom-seating is required for proper O-ring sealing. Pull back gently to confirm collet grip.
Step 04
Set bend radius generously, especially for constant-flex
Minimum radius 3-4x OD for 95A, 5-6x OD for 98A. For dynamic applications, use at least 2x the published minimum to maximize fatigue life. Sweep bends; install elbow PTC at corners rather than forcing a tight angle. Provide slack at the moving end so the tube doesn't go straight under cylinder extension — straight tubing in a flex application work-hardens at the entry point and fails there first.
Step 05
Pressurize and soap-test every joint
PU is the most forgiving polymer for PTC sealing. Most PU leaks resolve on a clean re-seat.
Step 06
Support static runs and protect dynamic runs
Static: P-clips or tube clips every 18-30 inches. Dynamic: support at the fixed end only; the moving end needs free flex with strain relief or service loop at the entry point. Install grommets or spiral-wrap at abrasion points.
Step 07
Protect against sunlight, ozone, and chemical exposure
Standard PU not UV-stable; outdoor runs need UV-stabilized PU or a conduit sleeve. For oil/coolant-prone locations, do not install PU — re-spec to PA12.
Step 08
Label and document
Mark every circuit with adhesive labels or color bands. Record install date, OD/color, durometer, fitting line, circuit ID. Multi-bore drops label each bore separately. Documentation prevents the next maintenance team from cutting in PE or PA12 where PU is required.
10Troubleshoot · top failures

Most returns trace to one of these causes.

Symptom
Most likely cause
Fix
PU cracked at the bend on a robot end-effector or hand-tool drop after weeks-to-months.
Wrong durometer (98A firm where 95A soft was needed), bend radius tighter than polymer minimum (work-hardening at the constant-flex point), insufficient slack at the moving end, or polymer degradation from oil-mist or solvent exposure.
For constant-flex, switch to soft 95A PU at the same OD. Verify bend radius is at least 2x the published minimum on dynamic runs. Add a service loop at the moving end. If chemistry exposure is present, the polymer is wrong — switch to PA12 for oil/coolant or FEP for solvent.
PU collapsed or kinked at a tight bend forced during install.
Bend radius forced tighter than minimum, typically because the installer fought the tube around a corner with no support.
Cut out the kinked section. Use a 90° PTC elbow at the corner rather than bending the tube. If bending is required, sweep gradually with a curved support.
PU leaking at a PTC fitting immediately after install.
Short insertion depth, cut face damaged or angled, or wrong fitting collet size for the actual tube OD.
Depressurize, withdraw, inspect. Re-cut square, mark insertion depth, push to flush. PU is the most forgiving for PTC sealing — leaks that persist after clean re-cut and re-seat point to fitting OD mismatch.
PU gone soft, swollen, or sticky near a coolant tank or solvent station.
Chemical attack from oil, cutting fluid, or hydrocarbon solvent. PU absorbs the chemistry, loses tensile, swells out of fitting tolerance, fails.
Polymer-mismatch problem — no PU spec resolves it. Replace with PA12 (for oil/coolant) or FEP (for solvent). Document the spec change in the customer's MRO. Re-polymer the full run from the chemistry source to the next isolation, not just the visibly degraded section.
PU embrittled, yellowed, or cracked along an outdoor run after one season.
UV degradation of unstabilized PU. Urethane-bond chemistry breaks under sustained UV; ozone exposure (near electrical equipment) causes similar damage.
Replace with UV-stabilized PU (carbon-black-loaded), or for indefinite outdoor, re-spec to PA12. Conduit sleeving adds protection but doesn't solve the polymer mismatch.
Coiled/self-storing PU has lost its recoil and hangs limp.
Permanent set in the polymer from sustained stretching, thermal exposure past memory limits, or chemical exposure degrading elastic recovery.
Replace the coil. Specify by working length, OD, fitting configuration. If thermal exposure exceeded 150°F, the application is wrong for PU.